FUNCTION (12) DATA READ PARAMETER TRACE

Use this function to read consecutive trace data from the control, re-read the last data set, or reset and re-read
the trace data from the beginning again.

Table 67 Host Transmission

Control Byte (5) definition:

00 = Reset and re-read from beginning
01 = Continue reading from end of the last data point that was read
02 = Re-read the prior data segment

Message Length = 8 bytes

Table 68 CX-1200 Response

Byte #

DESC

Decimal

1

2

3

4

5-245

246

247

248

STX

Length

Address Msg Error Data Field

ETX

CRC

Hex

2

12-248

1-99

0-255

<below>

3

0-65535

02

0C

01-63

00-FF

<below>

03

0000-FFFF

Data Field per Table 68
Length = 1 + [ 4 x Number of data points ]

Byte #

DESC

Decimal

5

6

7

8

9

Status/Error Code

Trace Data

Hex

0-32

-2147483648-2147483647

00-20

80000000-7FFFFFFF

Trace Read Status/Error Code

- 1 byte/response

Trace Data

- LONG (4 bytes/data point*)

*Maximum of 60 Data Points/Transmission ( 1 + [ 4 x 60] = 241 bytes )

Message Length = 12 to 248 bytes

Byte #

DESC

Decimal

1

2

3

4

5

6

7

8

STX

Length

Address Function

Control

ETX

CRC

Hex

2

8

1-99

12

0-2

3

0-65535

02

08

01-63

0C

00-02

03

0000-FFFF

Advertising