Aux analog output / analog output p1/1 – CONTREX CX-1200 User Manual

Page 124

Advertising
background image

5 - 31

AUX ANALOG OUTPUT / ANALOG OUTPUT P1/1

AO Mode

Analog Output Mode (CP-291) identifies the mode of operation and calibration that are used for the Auxiliary Board
Analog Output signal.

2 = Current
1 = Voltage (default)

AO RA

Analog Output Reference A (CP-292) scales the Auxiliary Board Analog Output from the units of the selected param-
eter to the units of the output, generally measured in volts or milliamps.

Val@AO RA

Value @ Analog Output Reference A (CP-293) scales the Auxiliary Board Analog Output from the units of the selected
parameter to the units of the output; generally measured in volts or milliamps. Enter the parameter value that corre-
sponds to AO RA (CP-292).

AO RB

Analog Output Reference B (CP-294) scales the Auxiliary Board Analog Output from the units of the selected param-
eter to the units of the output; generally measured in volts or milliamps. Enter the parameter value that corresponds
to VAL@AO RB (CP-295).

Val@AO RB

Value at Analog Output Reference B (CP-295) scales the Auxiliary Board Analog Output from the units of the selected
parameter to the units of the output, (generally measured in volts or milliampere). Enter the parameter value that
corresp

AO Parameter

Analog Output Parameter (CP-290) identifies the Monitor or Control Parameter that is used for the Auxiliary Analog
Output. When the Analog Output Parameter (CP-290) is set to “0”, the value of AO DIRECT (CP-365) is used as the
output.

NOTE: The following Monitor and Control Parameters are not available for the Analog Output Parameter (CP-290):

MP-17 ....... AnlgCal Ref A

MP-18 ....... AnlgCal Ref B

MP-22 .......... CO Max Bits

MP-23 ..... CO DAC Range

MP-24 ................. AO Bits

MP-25 ............. AO Signal

MP-26 .................... DI 7..0

MP-27 .................. DI 15..8

MP-29 ... KeyPad Lockout

MP-38 .............. Ld EU/Tm

MP-45 ............. Cntrl Loop

CP-290 ....... AO Parameter

AO Direct

Analog Out Direct (CP-465) is the value output (in volts or milliamps) at the Auxiliary Analog Board's analog output
when the AO Parameter (CP-290) is set to a “0”.

AO Bits

Analog Output Bits (MP-166) displays the present value, in DAC Bits, of the Auxiliary Analog Output.

AO Signal

Analog Output Signal (MP-167) displays the present value, in either volts or milliamps of the Auxiliary Analog Output,
relative to AO Mode (CP-291).

Advertising