7 - 33

Other Errors Returned From The Control Through Serial Communications:

00

=

OK

01

=

General Data Error

02

=

Res Byte Error

03

=

Invalid Parameter

04

=

String too Long

05

=

Out of Range

06

=

Not Allowed

07

=

Lockout During Run

08

=

Not Ready

09

=

Block Parameter Error

10

=

Block Value Error

11

=

Block Parameter Memory Limit

12

=

MIN Error

13

=

MAX Error

14

=

Invalid Command (PLC/Control Command Send)

15

=

Invalid Operand (PLC)

16

=

<END> Statement Missing (PLC)

17

=

PLC Program Memory Limit

18

=

Defaults Loaded

19

=

Backup Loaded

20

=

Backup Saved

21

=

Checksum Error

22

=

Faults Cleared

23

=

Test Passed

24

=

Test Failed

25

=

No Compare Parameter

26

=

Divide by Zero

27

=

Long Word Overflow

28

=

Parameter Transfer Limit Overflow

29

=

Memory Read request too long

30

=

Data Field Length Error

31

=

Message Function Request/Parameter NOT Processed

32

=

Invalid Function Request

Note:

In the ASCII2 protocol the error codes listed above are preceded by an “E” (e.g., “E32” indicates an
Invalid Function Request)