EDIT BLOCK 0 THROUGH 7

Blk0 Val 1 - Blk7 Val 16

Use the Block Values (CP-540 to CP-667) to assign Parameter Values to the Control Parameters that were designated
by name in the Edit Block Parms screens (CP-500 to CP-515). Edit Blocks 0-7 allow you to assign up to eight
different values to a single Control Parameter by entering a different Parameter Value in each of the Edit Block
screens (0-7). The graphic matrix below displays the interaction between the Edit Block Parms screens and the Edit
Block 0-7 screens.

The block of Control Parameters and corresponding values that is in current use, is called the “active” block. The
active block is selected in either the Keypad Block Select (CP-479) or in the PLC (in combination with the Digital
inputs). The active block is monitored by Active Block (MP-51). For more information on selecting and monitoring
the active block, refer to System Monitoring (MP) / System Monitor / Control Overrides.

The default setting in the Val 1 line for Blocks 0-7 (Page 1), is Master Setpoint. This line can be reassigned in the
Edit Block Parms screens.

The assignment is reflected on the
corresponding value line in all eight
of the Edit Block screens —>

Enter Parameter
Values in the
Edit Block (0-7)
screens.

EDIT BLOCK 0

<Active Block>

5

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk0 Val 1

Blk0 Val 2

Blk0 Val 3

Blk0 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 1

10

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk1 Val 1

Blk1 Val 2

Blk1 Val 3

Blk1 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 2

15

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk2 Val 1

Blk2 Val 2

Blk2 Val 3

Blk2 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 3

20

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk3 Val 1

Blk3 Val 2

Blk3 Val 3

Blk3 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 4

25

*

0

*

0

*

0

*

P1/4

®NOT USED

Blk4 Val 1

Blk4 Val 2

Blk4 Val 3

Blk4 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 5

30

0

*

0

*

0

*

P1/4

®NOT USED

Blk5 Val 1

Blk5 Val 2

Blk5 Val 3

Blk5 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 6

35

0

*

0

*

0

*

P1/4

®NOT USED

Blk6 Val 1

Blk6 Val 2

Blk6 Val 3

Blk6 Val 4

®NOT USED

®NOT USED

->Line Spd SP

EDIT BLOCK 7

40

0

*

0

*

0

*

P1/4

->NOT USED

Blk7 Val 1

Blk7 Val 2

Blk7 Val 3

Blk7 Val 4

->NOT USED

->NOT USED

->Line Spd SP

<—

<—

<—

<—

<—

<—

<—

NOTE: In this example, the blocks are used to assign
eight different values to the Line Speed Setpoint.
Line Spd SP (CP-210) is assigned to the blocks
in the Edit Block Parms screen. Then the eight values
for Line Speed Setpoint are assigned in the Edit Block
Screens. The block (0-7) that is active determines
which of the eight Line Speed Setpoint values is used.

EDIT BLOCK PARMS

210

*

0

*

0

*

0

*

P1/4

->Line Spd SP

->NOT USED

Block Parm 1

Block Parm 2

Block Parm 3

Block Parm 4

->NOT USED

->NOT USED

The assigned
Control
Parameter's
name appears
on the line
below —>

Control Parameters (up to 16) have been
assigned in the Edit Block Parms sceens.

<—

<—

<—

Advertising