Figure 24 Batch Reset

Batch Reset

2

3

J7

DI_9

Com

Figure 26 Open Loop


Open Loop

3

5

J7

Com

DI_11

Figure 25 Re-Learn

Re-Learn

3

4

J7

Com

DI-10

Batch Reset

(J7 pins 2,3)
Digital Input 9

Batch Reset is a momentary input. When it is closed, the CX-
1200 resets the internal batch counter to zero.

Open Loop

(J7 pins 6, 3)
Digital Input 11

Open Loop is a maintained input. When it is closed (Open
Loop), it the Control Output is adjusted in response to the
setpoint changes only and feedback and error are ignored.
When it is open (Closed Loop), the control algorithm adjusts
the Control Output to reduce the error to zero.

Re-Learn

(J7 pins 4, 3)
Digital Input 10

Re-Learn is a maintained input. When it is closed, . As a
maintained input, Re-Learn is only active when the operator
device is closed.

Advertising