7 - 11

FUNCTION (05) CONTROL COMMAND SEND

Table 7-10 Host Transmission

Character #

1

2

3

4

5

6

7

8

9

10

11

12

DESC

ASCII

STX

Address

Function

Command

^B

0-9

0-9

0

5

0-2

0-9

^C

0-F

0-F

0-F

0-F

ETX

CRC (0000 - FFFF)

Data Field - Control Command - 2 characters
Valid Control Commands:

01 = F-Stop.
02 = R-Stop.
03 = H-Stop.
04 = Run.
05 = Jog Forward.
06 = Jog Reverse.
07 = Jog Stop.
09 = Reset Integral.
10 = Preset FB Position.
11 = Preset LD Position.
12 = Reset Position Error.
13 = Preset FB & LD Position.
14 = Preset FB, LD, & Reset Position Error.
17 = Negate Scaled Reference.
21 = Bypass Ramp.
22 = Stop Ramp.
23 = Open Loop.
24 = Stop Integral.

Message Length = 12 characters.

Table 7-11 CX-1200 Response

Character #

1

2

3

4

5

6

7

8

9

10

11

12

DESC

ASCII

STX

Address

Msg Error

Cmd Error

^B

0-9

1-9

0-F

0-F

0-3

0-9

^C

0-F

0-F

0-F

0-F

ETX

CRC (0000 - FFFF)

Data Field - Command Error Code - 2 characters.

Message Length = 12 characters.