7 - 56

FUNCTION (13) READ PARAMETER TRACE DATA/RE-READ PREVIOUS

Use this function to read the trace status byte.
Status Byte Definitions:

Bit 7

=

Not Defined (always 0)

Bit 6

=

Not Defined (always 0)

Bit 5

=

Not Defined (always 0)

Bit 4

=

Not Defined (always 0)

Bit 3

=

(1) Trace Complete (0) Not Complete

Bit 2

=

(1) Trace Active (trigger encountered, collecting data) (0) Not Active

Bit 1

=

(1) Trace Enabled (waiting for trigger to occur) (0) Disabled

Bit 0

=

(1) Trace Enabled (0) Disabled

Table 69 Host Transmission

Byte #

DESC

Decimal

1

2

3

4

5

6

7

Hex

STX

Length

Address

Function

ETX

CRC

2

8

1-99

13

3

0-65535

02

08

01-63

0D

03

0000-FFFF

Message Length = 7 bytes

Table 70 CX-1200 Response

Byte #

DESC

Decimal

1

2

3

4

5

6

7

8

STX

Length

Address Msg Error

Status

ETX

CRC

Hex

2

8

1-99

0-255

0-8

3

0-65535

02

08

01-63

00-FF

00-08

03

0000-FFFF

Status Bytes values:

Bits:

76543210

Decimal:

Description

00000000

= 0

Trace Disabled, no data collected.

00000001

= 1

Trace Enabled.

00000011

= 3

Trace Enabled, waiting for trigger.

00000101

= 5

Trigger Encountered, collecting data.

00001000

= 8

Trigger Complete, collecting data.

Message Length = 8 bytes