Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-205 LdSyncDvd

Lead Sync Divide (CP-205) can be used to reduce the sync rate of the CX-1200 for those processes that may need the
maximum sync rate of 20 pulses per second. The lead sync pulses are divided by the LdSyncDvd (CP-205) value before
being submitted to the synchronization routine.

Minimum Value: 1

Maximum Value: 255

Default Value: 1

Units: Coded

CP-206 FbSyncDvd

Feedback Sync Divide (CP-206) can be used to reduce the sync rate of the CX-1200 for those processes that may need
the maximum sync rate of 20 pulses per second. The follower sync pulses are divided by the FbSyncDvd (CP-206) value
before being submitted to the synchronization routine.

Minimum Value: 1

Maximum Value: 255

Default Value: 1

Units: Coded

CP-207 LdOfstSource

Lead Offset Source (CP-207) identifies the source of the Lead Sensor Offset, which may be used to set a distance offset
to the lead position. Lead Offset Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = Lead Sensor Offset (CP-341) (default)

Minimum Value: 1

Maximum Value: 3

Default Value: 1

Units: Coded

CP-208 FbOfstSource

Follower Offset Source (CP-208) identifies the source of the Follower Sensor Offset, which may be used to set a
distance offset to the follower position. Follower Offset Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = Follower Sensor Offset (CP-351) (default)

Minimum Value: 1

Maximum Value: 3

Default Value: 1

Units: Coded

CP-209 Time Base

Time Base (CP-209) is the denominator, which represents the time (Tm) in the EU/Tm equation. The equation scales the
Frequency Inputs (FI1 and FI2) to EU/Tm.

3 = per Hour
2 = per Minute (default)
1 = per Second