Offsets & phase p1/2 – CONTREX CX-1200 User Manual

Page 116

Advertising
background image

5 - 23

OFFSETS & PHASE P1/2

LdOfstSource

Lead Offset Source (CP-207) identifies the source of the Lead Sensor Offset, which may be used to set a distance offset
to the lead position. Lead Offset Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = LdSnsrOfst (CP-341) (default)

FbOfstSource

Follower Offset Source (CP-208) identifies the source of the Follower Sensor Offset, which may be used to set a
distance offset to the follower position. Follower Offset Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = FbSnsrOfst (CP-351) (default)

PhaseSource

Phase Source (CP-356) identifies the source of the Non-Sync Phase, which may be used to set a distance offset to the
non-sync follower position. Phase Sources are:

3 = Analog Input 2
2 = Analog Input 1
1 = NonSyncPhase (CP-357) (default)

LdNetOfst

Lead Net Offset (MP-15) displays the resultant Net-Offset applied to the lead position after considering the LdSnsrDist
(CP-340) and the LdSnsrOfst (CP-341) values. LdNetOfst (MP-15) is the final resultant offset inside a lead job size.

FbNetOfst

Follower Net Offset (MP-25) displays the resultant Net-Offset applied to the follower position after considering the
FbSnsrDist (CP-350) and the FbSnsrOfst (CP-351) values. FbNetOfst (MP-25) is the final resultant offset inside a
follower job size.

SyncFlgDif

Sync Flag Difference (MP-29) displays the difference, in Follower EU’s, between the position of the Lead and Follower
sync pulses.

Advertising