C - 13

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

MP-102 DO 7..0

Digital Output 7..0 (MP-102) displays the value of the “J2” digital outputs. A ‘1’ in the bit location (see graphic below)
indicates an active “low voltage” condition on the corresponding open collector output (which would sink DC
current).

Drive Enable

Batch Done

Sync Alarm

Fwd/Rvs

Lead Sync Absent

Foll Sync Absent

Hi/Low Seed Alarm

Zero Speed

Minimum Value: 00000000

Maximum Value: 11111111

Units: Coded

MP-103 KeyPad Lockout

Keypad Lockout (MP-103) displays the Keypad Lockout status. The Keypad Lockout is active when “On” is
displayed. When Keypad Lockout is active, Control Parameter values can not be changed, with the exception of the
Control Parameters that are exempted by CP’s 480-489. The Keypad Lockout is not active when “OFF” is displayed.
When the Keypad Lockout is not active, any Control Parameter can be changed.

Minimum Value: 0

Maximum Value: 1

Units: Coded

MP-107 TMR4 TIME

Timer 4 Time (MP-107) displays the elapsed time, in seconds, for Timer 4 during the delay part of its operation.

Minimum Value: 0

Maximum Value: 86400

Units: Seconds