CONTREX CX-1200 User Manual

Page 406

Advertising
background image

C - 60

(Continued)

Appendix C: Parameter Summary Numeric Quick Reference (continued)

CP-390 Cmpr3 Val

Enter a value in Cmpr3 Val (CP-390) that will be compared to the Monitor Parameter in Cmpr3 Parm (CP-382), using the
comparison type that you entered in Cmpr3 Type (CP-386). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr3 Out bit (62) in the PLC to “1”.

Minimum Value: -9999999

Maximum Value: 9999999

Default Value: 200

Units: same as the selected MP

CP-391 Cmpr4 Val

Enter a value in Cmpr4 Val (CP-391) that will be compared to the Monitor Parameter in Cmpr4 Parm (CP-383), using the
boundary type that you entered in Cmpr4 Type (CP-387). If the comparison that is established by these three
parameters is “true”, then the PLC sets the Cmpr4 Out bit (63) in the PLC to “1” .

Minimum Value: -9999999

Maximum Value: 9999999

Default Value: 72

Units: same as the selected Monitor Parameter

CP-396 Copy Source 1

Copy Source 1 (CP-396) identifies the CP or MP whose value is copied to Copy Dest 1 (CP-397) when a 0 to 1 transition
occurs in the Data Copy 1 PLC bit (160).

Minimum Value: 1

Maximum Value: 667

Default Value: 230

Units: CP or MP

CP-397 Copy Dest 1

Copy Dest 1 (CP-397) identifies the CP that takes on the value of the CP or MP identified by Copy Source 1 (CP-396)
when a 0 to 1 transition occurs in the Data Copy 1 PLC bit (160).

Minimum Value: 201

Maximum Value: 667

Default Value: 230

Units: CP or MP

CP-398 Copy Source 2

Copy Source 2 (CP-398) identifies the CP or MP whose value is copied to Copy Dest 2 (CP-399) when a 0 to 1 transition
occurs in the Data Copy 2 PLC bit (161).

Minimum Value: 1

Maximum Value: 667

Default Value: 235

Units: CP or MP

CP-399 Copy Dest 2

Copy Dest 2 (CP-399) identifies the CP that takes on the value of the CP or MP identified by Copy Source 2 (CP- 398)
when a 0 to 1 transition occurs in the Data Copy 2 PLC bit (161).

Minimum Value: 201

Maximum Value: 667

Default Value: 235

Units: CP or MP