5 - 111

DIGITAL I/O

The PLC / Digital I/O, (page 1) screen displays parameters that are associated with the digital inputs for the
PLC (DI-8 through DI-15). The DI-14 and DI-15 are routed to the Scroll Up bit (168) and Scroll Dn bit
(169) respectively by the default PLC program. This allows these digital inputs to control the remote scroll-
up and remote scroll-down function. The remote-scroll function can be assigned to almost any of the Control
Parameters. Use Remote Scroll (CP-400) to select the Control Parameter that you want to assign to the
remote scroll function. The rate of change when the PLC Bit is “1” (On or Digital Input active with default
PLC program) is determined by Rmt Scroll Rate (CP-401). This is the number of increments/decrements to
the least significant digit every second that the PLC bit (input) is active. Use Table 5-1 for the time-between
increments or decrements of the various remote scroll rates.

DI 1 Shot (CP-402) determines which digital inputs will cause the corresponding PLC bit (8-15) to be “1”
(On) for one PLC scan (one-shot) when an open-to-closed (active) transition occurs on the input. This is the
default one-shot for the PLC.

Remote Scroll Rate

Increment Interval

(Time)

Number of 10 - mSec

1

Samples per Interval

10

5

4

3

2

15

14

12

11

50

30

25

20

100

1000 mSec = 1 Sec

500 mSec

100 mSec

200 mSec

250 mSec

333 mSec --> 330 mSec

67 mSec --> 60 mSec

50 mSec

40 mSec

33 mSec --> 30 mSec

20 mSec

10 mSec

71 mSec --> 70 mSec

83 mSec --> 80 mSec

91 mSec --> 90 mSec

100

10

20

25

33

50

6

7

8

9

2

3

4

5

1

Table 5-1 Remote Scroll Rates