CONTREX CX-1200 User Manual

Page 254

Advertising
background image

7 - 15

Message Error Bits Definitions:

Bit 7

=

(1) CRC Failure

Bit 6

=

(1) Buffer Overflow

Bit 5

=

(1) ETX Not Received/Data Field Error

Bit 4

=

(1) Invalid Function/Data Error

Bit 3

=

(1) Over-Run Error

Bit 2

=

(1) Noise Error

Bit 1

=

(1) Framing Error

Bit 0

=

(1) Parity Error

Example:

“86” = the number 10000110 (binary) would indicate a CRC failure with Noise errors and Framing
errors occurred when the transmission message was received.

Other Errors Returned From The Control Through Serial Communications:

00

=

OK

01

=

General Data Error

02

=

Res Byte Error

03

=

Invalid Parameter

04

=

String too Long

05

=

Out of Range

06

=

Not Allowed

07

=

Lockout During Run

08

=

Not Ready

09

=

Block Parameter Error

10

=

Block Value Error

11

=

Block Parameter Memory Limit

12

=

MIN Error

13

=

MAX Error

14

=

Invalid Command (PLC/Control Command Send)

15

=

Invalid Operand (PLC)

16

=

<END> Statement Missing (PLC)

17

=

PLC Program Memory Limit

18

=

Defaults Loaded

19

=

Backup Loaded

20

=

Backup Saved

21

=

Checksum Error

22

=

Faults Cleared

23

=

Test Passed

24

=

Test Failed

25

=

No Compare Parameter

26

=

Divide by Zero

27

=

Long Word Overflow

28

=

Parameter Transfer Limit Overflow

29

=

Memory Read request too long

30

=

Data Field Length Error

31

=

Message Function Request/Parameter NOT Processed

32

=

Invalid Function Request

Advertising