(7) Setting functions (SCARA axis)

Set the velocity (Vel), acceleration (Acc), deceleration (Dcl) and inching distance (Inc.) to be used when

the actuator is operated using the various buttons.

Fig. 6.28 Settings of Velocity, Acceleration, Deceleration and Inching Distance

Jog/Inc

Vel [mm/sec], Acc [G], Dcl [G], Inc [mm]

The above settings are effective on both the work and tool coordinate systems.

Vel [%], Acc [%], Dcl [%], Inc [deg]

The above settings are effective only when the "each Axis" system is selected.

The jog button functions as the incremental button, if a numeric value (0.01 to 1.00) is entered in

the Inc field under Setting Function.

Move

Vel [%], Acc [%], Dcl [%]

Set the moving speed that applies when the MV button is clicked.

Movement occurs in the form of PTP operation. Each percentage setting indicates a percentage

with respect to a corresponding parameter setting.

Vel [%] (percentage with respect to "Axis Parameter No. 28: "PTP speed MAX")

Acc [%] (percentage with respect to "Axis Parameter No. 134: "PTP acceleration MAX")

Dcl [%] (percentage with respect to "Axis Parameter No. 135: "PTP deceleration MAX")