13. How to Reset an

Absolute Encoder

174

13.2 Scara Axis

13.2.1 Absolute Reset Preparation

The following jigs are required to perform an absolute reset:

x

Absolute Reset Adjustment jigs

Type Remarks

JG-1 Arm length 500/600

JG-2 Arm length 250/300/350

JG-3 Arm length 700/800

JG-4 Arm length 500/600 high-speed type

JG-5 Arm length 120/150/180

Connect the cables of the actuator, controller and PC to make an operable status. Always check operation

of the EMG switch before performing work. The absolute reset adjustment jig is always required to

perform an absolute reset for the rotation axis and vertical axis, but not always required for arm 1 and arm

2. (Rotation data can be reset as long as positioning preciseness of "center of positioning mark label ± 1

graduation" is ensured.)

Fig. 14.6 Example of Absolute Reset Adjustment Jig (Type JG-1)

x

Performing work without understanding inspection and maintenance work thoroughly may cause an

accident resulting in injury or death.

x

Post a sign "MEN WORKING" to prevent other workers from operating the controller, operation panel or

other equipment.

Warning

Plate

Pin

Advertising