13. How to Reset an

Absolute Encoder

194

13.3.2 Starting the Absolute Reset Menu (Ball-screw Spline Adjustment Window)

(1) Start the ball-screw spline adjustment window from the PC software.

Fig. 14.41 Absolute Reset Window Launching Operation

(2) The ball-screw spline adjustment window starts.

When a linear movement axis number is selected, "Rotational Movement Axis Number (Mating Axis

Number)" and "Encoder Type" are displayed.

z

Ball-screw spline adjustment is performed using a linear movement axis and a rotational movement

axis as a pair. Since the adjustment procedure includes items that require robot operation, confirm

the range of operation of the actuator, absence of obstructions, etc., to make sure the robot can be

operated.

Fig. 14.42 Absolute Reset Window