13. How to Reset an

Absolute Encoder

179

Arm 1

(Arm length 250/300/350)

Arm 2

(Arm length 250/300/350)

Fig. 14.15 Arm length 250/300/350 Reference Position

(Note) When performing an absolute reset for arm 1 of

IX-NNN2515, rotate arm 2 slightly then set with an adjustment jig

(pin) to set it.

x

Always press the EMERGENCY STOP switch before setting an adjustment jig. Failure to do so may

cause the actuator to malfunction and result in a serious accident.