IAI America IA-101-X-USBMW User Manual
Page 157
10. Coordinate System Definition Data Edit W
indow
149
ޓ
ޓ
ޓ
;D
:D 㧙
<D
<D
㧗:D
㧗;D
㧙;D
:D
:D
#
$
%
&
'
(
)
*
[1] Set simple interference check zone No. 1
as a rectangular solid.
A: Xb=475, Yb=-50, Zb=150, Rb=0
G: Xb=400, Yb=50, Zb=200, Rb=180
If Rb is outside the 0 to 180°range, entry
into this rectangular solid is not detected.
[2] Set simple interference check zone No. 2
as an area where Yb is 425 mm or more.
[3] Set simple interference check zone No. 3
as an area where Xb is -400 mm or less
and Zb is 130 mm or more.
Simple interference
check zone No. 2
Simple interference
check zone No. 3
Simple interference
check zone No. 1
Setting example of simple interference check zones
Define simple interference check zones No. 1, No. 2 and No. 3 as shown below:
Shown below is the data edit screen to define simple interference check zones when simple interference
check zones No. 1, No. 2 and No. 3 are set respectively.