IAI America IA-101-X-USBMW User Manual

Page 157

Advertising
background image

10. Coordinate System Definition Data Edit W

indow

149

ޓ

ޓ

ޓ

;D

:D 㧙

<D

<D

㧗:D

㧗;D

㧙;D

:D

:D

#

$

%

&

'

(

)

*

[1] Set simple interference check zone No. 1

as a rectangular solid.

A: Xb=475, Yb=-50, Zb=150, Rb=0

G: Xb=400, Yb=50, Zb=200, Rb=180

If Rb is outside the 0 to 180°range, entry

into this rectangular solid is not detected.

[2] Set simple interference check zone No. 2

as an area where Yb is 425 mm or more.

[3] Set simple interference check zone No. 3

as an area where Xb is -400 mm or less

and Zb is 130 mm or more.

Simple interference

check zone No. 2

Simple interference

check zone No. 3

Simple interference

check zone No. 1

Setting example of simple interference check zones

Define simple interference check zones No. 1, No. 2 and No. 3 as shown below:

Shown below is the data edit screen to define simple interference check zones when simple interference

check zones No. 1, No. 2 and No. 3 are set respectively.

Fig. 10.15 Simple Interference Check Zone Definition Coordinates Setting Screen

Advertising