11. Monitor

165

Save the maintenance

information data to a file

(CSV format).

Transfer the data of entered new

values to the controller.

Print the maintenance

information data.

Initialize all maintenance information

data. (This button is displayed only

when there is a maintenance

information data error.)

A new value can be entered by the following methods:

• Double-click the cell.

• Press the "Ctrl" and "Space" keys together.

• Press a number key.

Only the alert function threshold can be changed.

If the system memory backup battery is installed, the error list contents will not be cleared even if the

power is turned OFF.
When clearing the error list contents, click the alarm list clear

key. A warning in Fig. 11.18 will be

displayed. Clicking Yes will clear the error list contents.

Fig. 11.21 Confirmation

* When trouble occurs, you may be requested to send the error list saved in a file to resolve the problem at

an early stage. The error list file cannot be opened by this PC interface software.

(8) Maintenance information screen

The total number of times the actuator has moved, and total distance travelled by the actuator, are

displayed.

This screen is displayed on the X-SEL-R/S, RX/SX or RXD/SXD controller.

Fig. 11.22 Maintenance Information

Total number of movements: Indicates the accumulated total of times the actuator has moved

Thresholds for total number of movements: Indicates the thresholds for the total number of movements

Total distance traveled [m]: Indicates the accumulated total of distance travelled by the actuator

Thresholds for total distance traveled [m]: Indicates the thresholds for the total distance travelled