IAI America IA-101-X-USBMW User Manual

Page 219

Advertising
background image

13. How to Reset an

Absolute Encoder

211

(9) Click following process button sequentially. When each processing finishes, red arrow will move to next

process.

[1] Controller error reset

[2] Servo off

[3] Simple ABS unit status reset

[4] Excitation detection completion status clear

[5] Servo On

[6] Home return

[7] Absolute reset

[8] Absolute reset completion confirmation

After clicking [Simple ABS unit status reset] button, Warning dialog of starting absolute reset will appear.

Click [Yes (Y)].

Fig. 14.72 Warning

Dialog will appear again to confirm. Click [Yes (Y)] to process.

Fig. 14.73 Warning

After finished processing [Absolute reset completion confirmation], red arrow will be back to normal

display as same as (8). If there is another axis to perform absolute reset, select axis of symmetry here,

then process from (8). To finish processing, click [close] button to close the [Absolute reset] window.

(Note) To process several axis absolute reset, finish process of (8) to (9) for all of axis before start

proceeding "(10) Software reset" explained below.

Advertising