11. Monitor

159

Fig. 11.10 Warning Message

The status (ON/OFF) of each input port as recognized by the controller changes the moment the debug

filter is cleared or controller operation mode (MANUAL or AUTO) is changed.

(1) Upon clearing a filter

Actual input status

Filter type

ON

OFF

ON

————

ON ĺ OFF

OFF

OFF ĺ ON

————

(2) Upon switching the controller mode from MANUAL to AUTO

Actual input status

Filter type

ON

OFF

ON

————

ON ĺ OFF

OFF

OFF ĺ ON

————

(3) Upon switching the controller mode from MANUAL to AUTO and then back to MANUAL

Actual input status

Filter type

ON

OFF

ON

————

OFF ĺ ON

OFF

ON ĺ OFF

————

* Changing the controller mode (MANUAL or AUTO) will not clear debug filters.

Accordingly, changing the controller mode back to MANUAL from AUTO will make

effective again the debug filters that were set in the previous MANUAL mode.

If any function is assigned to an input port, the applicable process will be executed. Exercise caution

against start of the following operations and others.

x

Functions assigned to input ports, such as program start and homing of all valid axes

x

SEL programs that use branching based on input condition

x

SEL programs that include commands for monitoring input port statuses

(WTON, WTOF, IN, INB, HOLD, CANC, JBWF, JBWN, JFWE, JFWN, etc.)

x

Other processes executed according to the input port statuses as monitored (recognized) by the

controller