Appendix – IAI America IA-101-X-USBMW User Manual

Page 233

Advertising
background image

16.
Appendix

225

16. Appendix

16.1 Parameter Recovery Method for X-SEL-P/Q, PX/QX, R/S, RX/SX and RXD/SXD

Controllers

If parameter data is lost during parameter writing to the flash ROM due to main power OFF or any other factor,

all parameters will be rewritten to initial values. In the case of the X-SEL-P/Q or PX/QX controller, an error will

be detected after power reconnection or software reset since system-specific settings are lost immediately

after parameter initialization.

Under such conditions, all parameters cannot be transferred to the controller.

The recovery method in that case is explained below.

Note: This method is intended to write the parameter data back to the controller for recovery. Please note

that serious effects such as home displacement, inoperability and error occurrence may result when

recovery parameters are transferred to any controller other than the target one, even if the model is

the same