10. Coordinate System Definition Data Edit W

indow

150

Fig. 10.16 Simple Interference Check Zone Definition Coordinates Setting Screen (X-SEL-RXD/SXD)

Zone No.:

Indicates the zone number.

Coordinate No.: Indicates the coordinate number. Coordinate 1 and Coordinate 2 are available.

Physical/Expansion Output Port No./Global Flag No.:

Select a desired output number to be output when the axis enters the check zone. (In

the case of the X-SEL-RX/SX or RXD/SXD controller, an expansion output port number

can also be entered.)

Error Type:

Select a desired type of errors.

0 = Do not handle errors.

1 = Output message level errors.

2 = Output operation-cancellation level errors.

(For Axis 5 to Axis 8, this item is displayed only on the X-SEL/RXD/SXD controller.)

(Note) Contact area data for two SCARA robots (Axis 1 to Axis 4, and Axis 5 to Axis 8) cannot be set for

one check zone.