14. Supplemental Information on

Controller Menu Items

215

14.3.2 In the cases of SSEL, ASEL or PSEL Controllers

(1) Drive-source recovery request

[1] Case where a drive-source recovery request is required A drive-source recovery request is required

only in the following case:

x

When you specify any input port for the drive power cut-off release input signal (dedicated function),

drive power cut-off occurs. o recovery after the main cause of cut-off is solved.

[2] How to issue an operation pause release request An operation pause release request can be issued

using one of the following methods:

x

Set the I/O parameter (No.30 - No.45, No.251 - No.258) corresponding to the input port No. to 17

(specified input function value). (Refer to the list of I/O functions and I/O parameters in the SSEL,

ASEL or PSEL controller operation manual.)

Input the ON edge on the specified input port No.

x

From the software menu, execute Controller (C) o Request Drive Power Recovery (P).

(2) Operation pause release request

[1] An operation pause release request is required in any of the following methods: Only the following

case requires executing Request Release Pause:

x

When you set other parameter No.10 to 2, (emergency stop recovery release according to type =

continuous operation release [during automatic operation only], emergency stop during automatic

operation o recovery after release of emergency stop (operation pause release).

x

When you set other parameter No.11 to 2, (Deadman SW/Enable SW recovery according to type =

continuous operation recovery during automatic operation only), stop by Deadman SW or Enable

SW during automatic operation o recovery after emergency stop release (operation pause

release).

x

Specify any input port for the operation pause release signal (dedicated function). Set the I/O

parameter (No.30 - No.45, No. 251 - No.258) corresponding to the input port No. to 8 (specified

input function value). (Refer to the list of I/O functions and I/O parameters.)

OFF level input on the input port No. specified at automatic operation (pause operation) o recovery

after ON level input on the input port No. (operation pause release).

[2] How to issue an operation pause release request An operation pause release request can be issued

using one of the following methods:

• Specify any input port for the operation pause release signal (dedicated function). Set the I/O

parameter (No.30 - No.45, No.251 - No.258) input port No. corresponding to the input port No. to 7

(specified input function value). (Refer to the list of I/O functions and I/O parameters.)

Input the ON edge on the specified input port No.

• From the software menu, execute Controller(C) o Request Release Pause (L).

Note) If the case in [1] of (1) and any of the cases in [1] of (2) are present at the same time, a

drive-source recovery request must be issued first, followed by an operation pause release

request.