Selecting a cw power sweep trigger 3-55, Selecting a sweep trigger, 3-55, Selecting a cw power sweep trigger -55 – Anritsu 681XXC User Manual

Page 88

Advertising
background image

Selecting a
CW Power
Sweep
Trigger

There are three modes of triggering provided for the
CW power sweep—automatic, external, and single.
The sweep trigger is selectable from the CW Level
Sweep Trigger menu. The following is a description
of each trigger mode.

q

Auto (Automatic)

–The CW power sweep con-

tinually sweeps from its start power level to its
stop power level with optimal retrace time.

q

External

–The CW power sweep recurs when

triggered by an external TTL-compatible clock
pulse to the rear panel

AUX I/O

connector.

q

Single

–A single CW power sweep starts when

the trigger key is pressed. If a sweep is in prog-
ress when the key is pressed, it aborts and re-
sets.

To go to the CW Level Sweep Trigger Menu (below)
from the CW Level Sweep Ramp menu, press

Trigger Menu

.

To select a CW power sweep trigger mode, press its
menu soft-key. A message showing the CW power
sweep trigger mode selected appears on the right
side of the level mode title bar .

If you select the single sweep trigger mode, the
menu display changes, adding the menu soft-key
labeled

Trig

. Pressing

Trig

starts a single CW

power sweep. If a single CW power sweep is in prog-
ress, pressing

Trig

causes the sweep to abort and

reset.

Press

Previous Menu

to return to the CW Level

Sweep Ramp Menu display.