Caution – HT instruments SIRIUS89N User Manual

Page 67

Advertising
background image

SIRIUS89N

EN - 65

CAUTION

The instrument has the only I1 active auxiliary input, so please pay attention
while connecting the clamp. The instrument does not recognize any clamp
which is connected to the I2 or I3 inputs.



8.1.5. How to set the value of the transformer voltage ratio (TV RATIO)
The instrument can also be interfaced with step-down transformers in the equipment under
test: it can display the value of he voltages present on the primary winding of these
transformers. To do this it will be necessary to set the value of the transformers’ windings
ratio from 2:1 to 3000:1. The default is set at 1:1 for measurements of none transformer
systems. Select “TV RATIO” in the ANALYZER CONFIG menu. Set the desired value by
pressing the multifunction keys

F3 and F4.


8.1.6. How to enable/disable the password
The instrument is provided with a protective routine to avoid the risk of being disturbed or
interrupted during a recording or an energy measurement. Once a recording or a direct
energy measurement has been started (with the option “PASSWORD” enabled), after
about 3 minutes from the last key pressure or switch rotation it won’t be possible to press
START/STOP to stop the recording, “PASSWORD” will be displayed and it will be
necessary to insert the password.
In order to insert the password (which is not changeable), press the multifunction keys in
the following sequence (within 10 seconds):

F1, F4, F3, F2


If you wait more than about 10 seconds the display will return to the meter mode and the
instrument will continue recording. If you insert a wrong password the message “Password
error” will be displayed under “PASSWORD”. After a few seconds the display will return to
meter mode and the instrument will continue recording. In order to enable/disable this
option the correct password will have to be entered. The display will return to meter mode
and

START/STOP will have to be pressed again to stop the recording. You will then need

to re-enter the “ANALYZER CONFIG” menu and scroll up or down to the item
“PASSWORD: ON” using the multifunction keys

F1 and F2. Then turn the password off by

pressing the multifunction keys

F3 and F4.


Advertising