HT instruments SIRIUS89N User Manual

Page 83

Advertising
background image

SIRIUS89N

EN - 81

8.6. "POWER"

FUNCTION

This function permits to display in real time the RMS value of AC/DC voltage, the peak and
ThdV value and the waveform of the voltage, the RMS value of AC/DC currents, the peak,
Thdl value and the waveform of the current. Furthermore, the instrument calculates and
displays the value of the active, reactive and apparent power and the value of the power
factors and cos

ϕ.


8.6.1. Symbols
The position POWER has two working modes:

METER
WAVE


For voltage and current harmonics see paragraphs 8.4.3 and 8.5.3 respectively.

These modes will be described in detail in the next paragraphs.
The symbols used are described below:

Symbol Description
V1

Voltage RMS value

freq Network

frequency

I1

Current RMS value

P1 Active

power

Q1 Reactive

power

S1 Apparent

power

Pf1 Power

factor

dpf1

cos

ϕ

Tab. 3: Symbols used in the position

POWER

The symbols "

i" and "c" stand for reactive powers (Q), power factors (Pf) and cos

ϕ (dpf)

respectively inductive and capacitive.

Advertising