Page 165

Advertising
background image

Rockwell Automation Publication 750-IN001N-EN-P - April 2014

165

PowerFlex 750-Series AC Drives

60

0V A

C Inp

ut

(c

onti

nued

)

810V

DC

Inp

ut (c

ontinued

)

90

0 Hp

9

815

Hea

vy

20G

…E98

0

122

3

1470

76

9

90

0

1000

950

475

170

0

95

0

475

230

0

2300

95

0

899

1000

825

No

rm

al

20G

…E82

5

908

1260

77

9

90

0

1000

950

47

5

180

0

95

0

47

5

230

0

2300

95

0

91

0

1000

835

Li

ght

20G

…E76

0

919

78

8

90

0

1000

100

0

500

180

0

10

00

500

240

0

2400

10

00

921

1000

95

0 Hp

9

900

No

rm

al

20G

…E90

0

990

1368

84

9

90

0

1000

105

0

52

5

190

0

10

50

52

5

250

0

2500

10

50

99

3

1000

900

Li

ght

20G

…E82

5

990

84

9

90

0

1000

105

0

525

190

0

10

50

525

250

0

2500

10

50

993

1000

10

00 Hp

9

980

No

rm

al

20G

…E98

0

107

8

1470

92

5

90

0

1000

115

0

57

5

210

0

11

50

57

5

280

0

2800

11

50

1081

1000

980

Li

ght

20G

…E90

0

107

8

92

5

90

0

1000

115

0

575

210

0

11

50

575

280

0

2800

11

50

1081

1000

10

920

Hea

vy

20G

…E1K1

138

0

1665

86

8

90

0

1000

110

0

55

0

200

0

11

00

55

0

260

0

2600

11

00

1015

1000

11

00 Hp

9

104

5

Li

ght

20G

…E98

0

115

0

98

6

90

0

1000

125

0

625

220

0

12

50

625

300

0

3000

12

50

1152

1000

10

111

0

No

rm

al

20G

…E1K1

122

1

1665

10

48

90

0

1000

130

0

65

0

240

0

13

00

65

0

310

0

3100

31

00

1224

1000

12

00 Hp

10

122

0

Li

ght

20G

…E1K1

134

2

1464

11

51

90

0

1000

145

0

725

260

0

14

50

725

350

0

3500

35

00

1345

1000

12

50 Hp

10

119

0

Hea

vy

20G

…E1K4

178

5

2145

11

23

90

0

1000

140

0

70

0

250

0

14

00

70

0

340

0

3400

34

00

1312

1000

14

00 Hp

10

143

0

N

orm

al

20G

…E1K4

157

3

2145

13

50

90

0

1000

170

0

850

300

0

17

00

850

410

0

4100

41

00

1577

1000

15

00 Hp

10

153

0

Li

gh

t

20G

…E1K4

168

3

1836

14

44

90

0

1000

180

0

90

0

320

0

18

00

90

0

430

0

4300

43

00

1687

1000

(1)

“Ap

plied

Ra

ting

” r

efers t

o the mot

or tha

t wi

ll be c

onne

ct

ed to the driv

e.

F

or

exa

m

pl

e,

a “E420

” dr

iv

e ca

n

be use

d

in

Norm

al

D

ut

y mo

de

o

n

a 4

50

H

p mo

to

r, in

Heav

y

D

ut

y mo

de

o

n

a 3

50

H

p mo

to

r o

r in

L

ig

ht

D

ut

y mo

de

o

n

a 5

00

H

p mo

to

r. T

he

d

riv

e c

an

b

e p

ro

gr

ammed

for

each mod

e.

W

iring

and fuses can be siz

ed ba

sed

on th

e pr

ogramme

d mod

e.

Fo

r an

y giv

en driv

e c

atalog number

, N

or

m

al D

ut

y mod

e pr

ov

ides higher con

tinuous c

urr

en

t b

ut

smaller o

ver

load cu

rr

en

t with r

espec

t t

o Hea

vy D

ut

y mode

. S

ee

pa

ra

met

er 30

6 [D

ut

y

Ra

ting].

Re

fe

r t

o Spe

cif

ic

at

io

ns f

or a

n e

xpl

ana

tion of

Dut

y Ra

tings

.

(2

)

Thes

e A

C li

ne f

use

s (w

ith bl

ow

n f

use

indi

ca

to

rs)

ar

e

inc

lude

d in the

driv

e t

o

pr

ov

ide

driv

e s

hor

t ci

rc

uit pr

ot

ec

tion. A

C i

np

ut pr

ot

ec

tion dev

ic

es for branch c

irc

uit pr

ot

ec

tion based

on U

S

NE

C ar

e list

ed in

the

table

. E

ach driv

e ba

y has one f

use p

er ph

as

e.

(3)

M

inimum pr

ot

ec

tion devic

e siz

e is th

e l

ow

est ra

ted d

evi

ce

that sup

pl

ie

s m

ax

imum p

rot

ec

tion without nuisance trip

ping

.

(4)

M

aximum pr

ot

ec

tion devic

e siz

e is the hi

ghest r

at

ed devic

e tha

t sup

plies

driv

e pr

ot

ec

tion

. F

or U

S N

EC

, mi

nim

um si

ze

is

12

5%

of

motor FL

A. R

ating

s shown are ma

xi

mum

.

(5)

Circui

t B

rea

ke

r -

in

ve

rse

ti

m

e br

ea

ke

r. F

or U

S NEC, m

ini

mu

m s

iz

e is

1

25%

of

motor FL

A. R

ating

s s

hown are m

axi

m

um.

(6)

Rec

ommended Mot

or cir

cuit p

rot

ec

tor - Instan

taneous trip cir

cuit br

eak

er

. T

he trip setting

sh

ould

be set t

o the in

put curr

en

t of

the

driv

e and should be sized for the con

tinuo

us c

urr

ent

of

the syst

em

.

(7

)

Thes

e DC

li

ne f

use

s (w

ith bl

ow

n f

use

indi

ca

to

rs)

ar

e

inc

lude

d in the

driv

e t

o

pr

ov

ide

driv

e s

hor

t ci

rc

uit pr

ot

ec

tion.

Ap

pli

ed

Ra

ting

(1

)

Frame

Cont

.

Ou

tp

u

t

Amps

D

u

ty

Ca

ta

lo

g

Num

b

er

Ou

tp

u

t

O

ver

load Amps

Cont

inuous

AC

In

pu

t

AC

In

pu

t

Integra

l

Se

m

ic

on

d

u

ct

or

Fu

se

S

ize

(170M)

(2

)

D

C Ba

y t

o Ba

y

In

te

gral

Se

m

ic

on

du

ct

or

Fuse S

ize

(17

0M664

8)

AC

Input Protec

ti

on De

vices Recommended f

or

Branch

Circ

uit Protec

tion

(D

oes not ap

ply t

o 21G

D

riv

es with O

ptions)

Input

Q

ua

n

ti

ti

es

DC

In

pu

t

Integr

al

Se

m

ic

on

du

ct

or

Fu

se

S

ize

(1

70M62

53)

(7

)

D

ual

El

em

ent Ti

me Dela

y

Fu

se

N

on-

Time Dela

y F

u

se

Ci

rc

ui

t

Br

eak

er

Ma

x Si

ze

(5

)

Motor

Circuit

Protec

tor

(6

)

Co

ntinuo

us D

C

Input

1 mi

n

3 s

ec

Amps

Am

ps

Amps

1/

Phas

e

Min

(3)

2/

Ph

as

e

Mi

n

(3)

Ma

x

(4

)

1/

Phas

e

Min

(3)

2/

Ph

as

e

Mi

n

(3)

Ma

x

(4)

Amps

Amp

s

Advertising