239

PowerFlex 750-Series AC Drives

22-Series I/O Module

Table 59 - Input Mode Jumpers

Table 60 - TB1 Terminal Designations

20-750-2262C-2R (24 Volts DC)

20-750-2263C-1R2T (24 Volts DC)

20-750-2262D-2R (120 Volts AC)

Jumper
Position

Voltage Mode

Current Mode

Terminal

Name

Description

Related
Param

(5)

(5) I/O Module parameters will also have a Port designation.

Sh

Shield

Terminating point for wire shields when an EMC plate
or conduit box is not installed.

Sh

Ptc–

Motor PTC (–)

Motor protection device (Positive Temperature
Coefficient).

(2)

(2) See HW Input PTC on

page 242

for PTC data.

40
on Port X

Ptc+

Motor PTC (+)

Ao0–

Analog Out 0 (–)

Bipolar, ±10V, 11 bit & sign, 2 k ohm minimum load.
4-20 mA, 11 bit & sign, 400 ohm maximum load.

75
on Port X

Ao0+

Analog Out 0 (+)

Ao1–

Analog Out 1 (–)

85
on Port X

Ao1+

Analog Out 1 (+)

–10V

–10 Volt Reference

2k ohm minimum.

10VC

10 Volt Common

For (–) and (+) 10 Volt references.

+10V

+10 Volt Reference

2k ohm minimum.

Ai0–

Analog Input 0 (–)

Isolated

(3)

, bipolar, differential, 11 bit & sign.

Voltage Mode: ±10V @ 88k ohm input impedance.
Current Mode: 0-20 mA @ 93 ohm input impedance.

(3) Differential Isolation - External source must be maintained at less than 160V with respect to PE. Input provides high common mode

immunity.

50, 70
on Port X

Ai0+

Analog Input 0 (+)

Ai1–

Analog Input 1 (–)

60, 70
on Port X

Ai1+

Analog Input 1 (+)

24VC

24 Volt Common

Drive supplied logic input power.
200 mA max. per I/O module
600 mA max per drive

+24V

+24 Volt DC

Di C

Digital Input Common Common for Digital Inputs 0…5

Di 0

Digital Input 0

(1)

(1) Digital Inputs are either 24 Volts DC (2262C) or 115 Volts AC (2262D) based on module catalog number. Ensure applied voltage is

correct for I/O module.

24V DC (30V DC Max.) - Opto isolated
High State: 20…24V DC 11.2 mA DC
Low State: 0…5V DC
120V AC (132V AC Max.) 50/60 Hz

(4)

- Opto isolated

High State: 100…132V AC
Low State: 0…30V AC

(4) For CE compliance use shielded cable. Cable length should not exceed 30 m (98 ft).

1
on Port X

Di 1

Digital Input 1

(1)

Di 2

Digital Input 2

(1)

Di 3

Digital Input 3

(1)

Di 4

Digital Input 4

(1)

Di 5

Digital Input 5

(1)

ATTENTION: Risk of equipment damage exists. Ensure that the correct voltage is
applied to the I/O Module digital inputs. Refer to the I/O Module catalog number to
determine the voltage rating.

20-750-2262C-2R is rated 24 Volts DC

20-750-2263C-1R2T is rated 24 Volts DC

20-750-2262D-2R is rated 120 Volts AC

Ai0

Ai1

Ai0

Ai1

Sh
Sh
PTC–
PTC+
Ao0–
Ao0+
Ao1–
Ao1+
–10V
10VC
+10V
Ai0–
Ai0+
Ai1–
Ai1+
24VC
+24V
DiC
Di0
Di1
Di2
Di3
Di4
Di5