237

PowerFlex 750-Series AC Drives

Digital Output
Internal supply

20-750-1133C-1R2T

Main Control Board TB1

11-Series I/O Module TB2

Set Selection

Port X (11-Series I/O Module): P20 [TO0 Sel] = Port 0: P935 [Drive Status 1], bit 7 = Faulted

View Results

Port X (11-Series I/O Module): P5 [Dig Out Sts]

Digital Output
External supply

20-750-1133C-1R2T

PLC TB

11-Series I/O Module TB2

Set Selection

Port X (11-Series I/O Module): P20 [TO0 Sel] = Port 0: P935 [Drive Status 1], bit 7 = Faulted

View Results

Port X (11-Series I/O Module): P5 [Dig Out Sts]

11-Series I/O Module TB1 Wiring Examples (Continued)

Input/Output

Connection Example

Required Parameter Changes

24VC

+24V

T0
TC
T1

+24V
24VC

753

755

P3

P8

3

1

3

1

+24V

Common

T0
TC
T1

T0
TC
T1

OR

+24VDC

Common

PLC

1756-1B16

IN-9

IN-11
IN-13

IN-15

GND-1

IN-1
IN-3
IN-5
IN-7

GND-0

IN-8
IN-10
IN-12

IN14
GND-1

IN-0
IN-2
IN-4
IN-6
GND-0