Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual

Page 269

Advertising
background image

Rockwell Automation Publication 750-IN001N-EN-P - April 2014

269

PowerFlex 750-Series AC Drives

Figure 128 - 460V MP-Series, HPK-Series, or Allen-Bradley 1326AB-Series Motor and a Stegmann Rotary or
Rotary Encoder connected via a 2090-CFBM7DF-CEAAXX (Non-Flex) or -CEAFXX (Flex)

Set Universal Feedback parameter P6 [FB0 Device Sel] or P36 [FB1 Device Sel] to 2
“Hiperface SC.”

IMPORTANT

Do not use 120 Volts with the motor thermostat.

IMPORTANT

The Thermal Switch cannot be accessed using 2090-XXNFMP-SXX or 2090-CFBM7XX
series cables.

Universal Feedback Option

Module TB1

Stegmann

Encoder TB

B

A

D

C

L

N

WH/RD

RD

WH/GY

OR

BK/WH

BK

BK/WH

BK

WH/RD

RD

WH/GY
OR

WH/GN

GN

WH/GN

GN

REFSIN

+SIN

REFCOS

+COS

DATA- (RS485)

DATA+ (RS485)

SHIELD

POWER COMMON
POWER

OVERALL SHIELD

F

E

R TS+

S TS-

-Sn

+Sn

-Cs

+Cs

IS

OS

-Xc

-Xd

+Xd

-Hf

+Hf

5c

+5

+Xc

12c

-A

A

-B

B

-Z

Z

+12

Advertising