Table 93 - TB1 Terminal Designations

Table 94 - TB2 Terminal Designations

Terminal

Name

Description

-Sn

Sine (–)

Positive and negative terminals for Sine and
Cosine signals.
For use with 5V incremental encoders only.

+Sn

Sine (+)

-Cs

Cosine (–)

+Cs

Cosine (+)

Is

Inner Shield

Heidenhain inner shield terminal

Os

Outer Shield

Cable shield terminal

-Xc

Channel X Clock (–)

Negative clock terminal (Channel X)

+Xc

Channel X Clock (+)

Positive clock terminal (Channel X)

-Xd

Channel X Data (–)

Negative data terminal (Channel X)

+Xd

Channel X Data (+)

Positive data terminal (Channel X)

-Hf

Heidenhain Supply Feedback (–)

For incremental feedback applications, tie
terminal -Hf to 5c and terminal +Hf to +5 for
proper voltage regulation.

+Hf

Heidenhain Supply Feedback (+)

5c

Common

+5V Common

+5

+5 Volt DC Power

Power supply for encoder 250 mA

12c

Common

+12V Common

+12

+12 Volt DC Power

Power supply for encoder
(10.5V @ 250 mA)

-A

Encoder A (NOT)

Single channel or quadrature A input or
encoder output.

(1)

(1) Inputs support 5V incremental encoders only. The encoder outputs differential voltage is 3.3V.

A

Encoder A

-B

Encoder B (NOT)

Quadrature B input or encoder output.

(1)

B

Encoder B

-Z

Encoder Z (NOT)

Pulse or marker input or encoder output.

(1)

Z

Encoder Z

Terminal

Name

Description

-Hm

Home Input (–)

12V DC @ 9 mA to 24V DC @ 40 mA

+Hm

Home Input (+)

-R0

Registration Input 0 (–)

Positive and negative encoder registration
terminals.
12V DC @ 9 mA to 24V DC @ 40 mA

+R0

Registration Input 0 (+)

-R1

Registration Input 1 (–)

+R1

Registration Input 1 (+)

-Yc

Channel Y Clock (–)

Negative clock terminal (Channel Y)

+Yc

Channel Y Clock (+)

Positive clock terminal (Channel Y)

-Yd

Channel Y Data (–)

Negative data terminal (Channel Y)

+Yd

Channel Y Data (+)

Positive data terminal (Channel Y)

IMPORTANT

Only one linear feedback device can be connected to the option module. Wire the
device to either Channel X on TB1 or Channel Y on TB2.

-Sn
-Cs

IS

-Xc
-Xd
-Hf

5c

12c

-A
-B

-Z

+Sn
+Cs

OS

+Xc
+Xd
+Hf

+5

+12

A
B

Z

-Hm

-R0
-R1
-YC

-YD

+Hm

+R0
+R1
+YC

+YD