Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual

Page 264

Advertising
background image

264

Rockwell Automation Publication 750-IN001N-EN-P - April 2014

PowerFlex 750-Series AC Drives

Table 95 - Universal Feedback Incremental AquadB Encoder

Table 96 - Supported Encoders

Consideration

Description

Input

Differential or Single Ended operation, Constant Current Sink operation ~10 mA

3.5V DC minimum to 7.5V DC maximum sourcing 10 mA
minimum high state voltage of 3.5V DC
maximum low state voltage of 0.4V DC

Maximum Cable Length

30 m (100 ft) @ 5V

Maximum Input Frequency

250 kHz

Consideration

Heidenhain (EnDat)

SSI

Stegmann
(Hiperface)

BiSS

Stahl (linear)

Temposonics (linear)

Encoder Voltage Supply 5V @ 250 mA

10.5V @ 250 mA

10.5V @ 250 mA

10.5V @ 250 mA

External Supplied 24V

External Supplied 24V

High-Resolution Signal

Sine/Cosine 1V P-P

Sine/Cosine 1V P-P

Sine/Cosine 1V P-P

Sine/Cosine 1V P-P

n/a

n/a

Maximum Cable Length 100 m

100 m

90 m

100 m

100 m

100 m

Update Rate

(1)

102.4

µs

102.4

µs

102.4

µs

102.4

µs

0.5/1.0/1.5/2.0 ms

0.5/1.0/1.5/2.0 ms

Maximum Input
Frequency

163.8 kHz

163.8 kHz

163.8 kHz

163.8 kHz

n/a

n/a

(1) The Universal Feedback Encoder Option Module will acquire the position with the update rates displayed.