Bfd for ospf configuration example – H3C Technologies H3C S12500-X Series Switches User Manual

Page 173

Advertising
background image

159

Id IPv4.State IPv6.State MTU Type DIS

001 Up Down 1497 L1/L2 Yes/No

# Display information about IS-IS interfaces on Switch D.

[SwitchD] display isis interface

Interface information for IS-IS(1)

----------------------------------

Interface: Vlan-interface100

Id IPv4.State IPv6.State MTU Type DIS

001 Up Down 1497 L1/L2 No/Yes

The output shows that when the default DIS priority is used, Switch C is the DIS for Level-1, and
Switch D is the DIS for Level-2. The pseudonodes of Level-1 and Level-2 are 0000.0000.0003.01

and 0000.0000.0004.01.
#Configure the DIS priority of Switch A.

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] isis dis-priority 100

[SwitchA-Vlan-interface100] quit

# Display IS-IS neighbors on Switch A.

[SwitchA] display isis peer

Peer information for IS-IS(1)

----------------------------

System Id: 0000.0000.0002

Interface: Vlan-interface100 Circuit Id: 0000.0000.0001.01

State: Up HoldTime: 21s Type: L1(L1L2) PRI: 64

System Id: 0000.0000.0003

Interface: Vlan-interface100 Circuit Id: 0000.0000.0001.01

State: Up HoldTime: 27s Type: L1 PRI: 64

System Id: 0000.0000.0002

Interface: Vlan-interface100 Circuit Id: 0000.0000.0001.01

State: Up HoldTime: 28s Type: L2(L1L2) PRI: 64

System Id: 0000.0000.0004

Interface: Vlan-interface100 Circuit Id: 0000.0000.0001.01

State: Up HoldTime: 30s Type: L2 PRI: 64

# Display information about IS-IS interfaces on Switch A.

[SwitchA] display isis interface

Interface information for IS-IS(1)

----------------------------------

Interface: Vlan-interface100

Id IPv4.State IPv6.State MTU Type DIS

Advertising