H3C Technologies H3C S12500-X Series Switches User Manual

Page 328

Advertising
background image

314

[SwitchA] ripng 1

[SwitchA-ripng-1] quit

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] ripng 1 enable

[SwitchA-Vlan-interface100] quit

[SwitchA] interface vlan-interface 400

[SwitchA-Vlan-interface400] ripng 1 enable

[SwitchA-Vlan-interface400] quit

# Configure Switch B.

<SwitchA> system-view

[SwitchA] ripng 1

[SwitchA-ripng-1] quit

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] ripng 1 enable

[SwitchA-Vlan-interface100] quit

[SwitchA] interface vlan-interface 400

[SwitchA-Vlan-interface400] ripng 1 enable

[SwitchA-Vlan-interface400] quit

# Configure Switch C.

<SwitchC> system-view

[SwitchC] ripng 1

[SwitchC-ripng-1] quit

[SwitchC] interface vlan-interface 200

[SwitchC-Vlan-interface200] ripng 1 enable

[SwitchC-Vlan-interface200] quit

[SwitchC] interface vlan-interface 500

[SwitchC-Vlan-interface500] ripng 1 enable

[SwitchC-Vlan-interface500] quit

[SwitchC] interface vlan-interface 600

[SwitchC-Vlan-interface600] ripng 1 enable

[SwitchC-Vlan-interface600] quit

# Display the RIPng routing table on Switch B.

[SwitchB] display ripng 1 route

Route Flags: A - Aging, S - Suppressed, G - Garbage-collect

O - Optimal, F - Flush to RIB

----------------------------------------------------------------

Peer FE80::20F:E2FF:FE23:82F5 on Vlan-interface100

Destination 1::/64,

via FE80::20F:E2FF:FE23:82F5, cost 1, tag 0, AOF, 6 secs

Destination 2::/64,

via FE80::20F:E2FF:FE23:82F5, cost 1, tag 0, AOF, 6 secs

Peer FE80::20F:E2FF:FE00:100 on Vlan-interface200

Destination 3::/64,

via FE80::20F:E2FF:FE00:100, cost 1, tag 0, AOF, 11 secs

Destination 4::/64,

via FE80::20F:E2FF:FE00:100, cost 1, tag 0, AOF, 11 secs

Advertising