[Hub-PE-vsi-aaa-ldp] quit

[Hub-PE-vsi-aaa] quit

# Configure interface GigabitEthernet 3/1/3, bind VPLS instance aaa to the interface, and

specifying the attached CE as the hub-CE.

[Hub-PE] interface GigabitEthernet 3/1/3

[Hub-PE-GigabitEthernet3/1/3] l2 binding vsi aaa hub

[Hub-PE-GigabitEthernet3/1/3] quit

After completing previous configurations, issue the display vpls connection command on the PEs. You will
see that a PW connection in up state has been established.

Configuring PW redundancy for H-VPLS access

Network requirements

As shown in

Figure 45

, UPE establishes a PW connection (U-PW) with NPE 1 and NPE 2, with the NPE

2 link as the backup. NPE 1 and NPE 2 each establish a PW connection (N-PW) with NPE 3. CE 3 is

connected to the network through NPE 3.
UPE is connected to NPE 1 through GigabitEthernet 3/1/2 and is connected to NPE 2 through

GigabitEthernet 3/1/3. NPE 1 is connected to NPE 3 through GigabitEthernet 3/1/5, and NPE 2 is

connected to NPE 3 through GigabitEthernet 3/1/6.
Configure a VPLS instance and configure it to support H-VPLS networking.

Figure 45 Network diagram

Configuration procedure

1.

Configure the IGP protocol (such as OSPF) on the MPLS backbone. (Details not shown)

2.

Configure UPE.
# Configure basic MPLS.

<Sysname> system-view

[Sysname] sysname UPE

[UPE] interface loopback 0

[UPE-LoopBack0] ip address 1.1.1.1 32

[UPE-LoopBack0] quit