GFK-1541B

Chapter 3 Programming Channel Commands

3-41

3

Minor Error Codes for Major Error Code 11H (at Remote Server PLC) -

Continued

3111H

Failure to register with backplane driver because the requested task is already
registered.

3211H

Unable to find resource necessary for backplane driver to process a service request.

3311H

Bad sequence number detected in the service request because it is already in use.

3411H

Invalid data detected that prevents backplane driver from completing a request.

3611H

More than the allowable byte length in a single transfer.

4811H

Memory resource problem detected.

4911H

Network buffer resource problem detected.

4C11H

Error detected while attempting to receive mailbox messages from the PLC.

4D11H

Timed out waiting to obtain a backplane transfer buffer.

4E11H

Timed out waiting to transfer a mailbox message to the PLC.

4F11H

Timed out waiting for PLC CPU response.

Minor Error Codes for Major Error Code 90H (at Client PLC)

Error Status

Application Interface Error Description

(Hexadecimal)

0190H

Timeout expired before transfer completed; still waiting on transfer.

0290H

Period expired before transfer completed; still waiting on transfer.

8190H

COMMREQ data block too short for the command.

8290H

COMMREQ data block too short for server PLC node address.

8390H

Invalid server memory type.

8490H

Invalid Program Name.

8590H

Invalid Program Block Name.

8690H

Zero server unit length is not allowed.

8790H

Server unit length is too large.

8890H

Invalid channel number.

8990H

Invalid time unit for period. (Maximum permitted 3965 hours)

8A90H

Period value is too large.

8B90H

Zero server memory starting address is not allowed.

8C90H

Invalid client memory type.

8D90H

Invalid server host address type.

8E90H

Invalid IP address integer value. (Must be 0–255)

8F90H

Invalid IP address class.

9090H

Insufficient TCP connection resources to do request.

9190H

Zero local starting address is not allowed.

9290H

Address length value invalid. Must be 4 for address type.

9390H

COMMREQ data block too short for Program Block name
(including 0 pad).

9490H

COMMREQ data block too short for Program name
(including 0 pad).

9590H

Internal API error. See PLC Fault Table or exception log for details. This
problem may occur due to the Ethernet Interface being asked to perform beyond its
capacity. Try transferring less data per message or establishing fewer
simultaneous connections.