TCP/IP Ethernet Communications for the Series 90™ PLC User's Manual

May 2002

GFK-1541B

3

Section 1: Section 2: Minor Error Codes for Major Error Code 90H (at Client

PLC) - Continued

9690H

Underlying TCP connection aborted (reset) by server end point.

9790H

Underlying TCP connection aborted by client end point.

9890H

The remote server has no Service Request Processor.

9A90H

Response to session request did not arrive in proper order.

9B90H

Session denied by server PLC.

9C90H

Data response did not arrive in proper order.

9D90H

Data response had unexpected size.

9E90H

Unrecognized COMMREQ command code.

A190H

Invalid CRS word memory type.

A290H

Failed an attempt to update the CRS word.

A490H

Address length value invalid. Must be 32 for Network Address name type.

B090H

Network Address name length error. The name cannot exceed 31 ASCII
characters and must be terminated with a NUL character (zero).

B190H

Specified Network Address name could not be resolved into an IP address.

B390H

Internal name resolution error. See PLC Fault Table or exception log for
details.

B590H

The channel the application is trying to access is owned by a different
protocol.