Sanyo KH2442 / CH2442 User Manual
Page 113
![background image](/manuals/155892/113/background.png)
I - 109
SM830082
1
2
3
4
5
1. Specifications
Indoor model: XH4242 / Outdoor model: CH4242
●
Cooling
●
Heating
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 V
208 V
230 V
208 V
230 V
208 V
230 V
208 V
Rating conditions
A
1.0
0.9
1.8
1.8
17.8
18.3
20.6
21.0
kW
0.2
0.17
0.36
0.34
3.64
3.58
4.2
4.09
Full load conditions
A
1.0
0.9
1.8
1.8
21.0
21.9
23.8
24.6
kW
0.2
0.17
0.36
0.34
4.41
4.33
4.97
4.84
Starting amperes
A
2
2
2
2
131
131
134
133.9
Cooling:
Rating Conditions
: Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature
95
°
F DB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature 115
°
F DB
Heating:
Rating Conditions
: Indoor Air Temperature
70
°
F DB / 60
°
F WB
Outdoor Air Temperature
47
°
F DB / 43
°
F WB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / —
°
F WB
Outdoor Air Temperature
45
°
F DB / 35
°
F WB
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 V
208 V
230 V
208 V
230 V
208 V
230 V
208 V
Rating conditions
A
0.9
0.8
1.8
1.8
18.9
19.6
21.6
22.2
kW
0.19
0.16
0.36
0.34
3.9
3.85
4.45
4.35
Full load conditions
A
0.9
0.8
1.8
1.8
21.2
22.8
23.9
25.4
kW
0.19
0.16
0.36
0.34
4.48
4.52
5.03
5.02
Starting amperes
A
2
2
2
2
131
131
133.9
133.8
Electrical characteristics
■
Electrical Data