1. Specifications

Indoor model: XH4242 / Outdoor model: CH4242

Cooling

Heating

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 V

208 V

230 V

208 V

230 V

208 V

230 V

208 V

Rating conditions

A

1.0

0.9

1.8

1.8

17.8

18.3

20.6

21.0

kW

0.2

0.17

0.36

0.34

3.64

3.58

4.2

4.09

Full load conditions

A

1.0

0.9

1.8

1.8

21.0

21.9

23.8

24.6

kW

0.2

0.17

0.36

0.34

4.41

4.33

4.97

4.84

Starting amperes

A

2

2

2

2

131

131

134

133.9

Cooling:

Rating Conditions

: Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature

95

°

F DB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature 115

°

F DB

Heating:

Rating Conditions

: Indoor Air Temperature

70

°

F DB / 60

°

F WB

Outdoor Air Temperature

47

°

F DB / 43

°

F WB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / —

°

F WB

Outdoor Air Temperature

45

°

F DB / 35

°

F WB

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 V

208 V

230 V

208 V

230 V

208 V

230 V

208 V

Rating conditions

A

0.9

0.8

1.8

1.8

18.9

19.6

21.6

22.2

kW

0.19

0.16

0.36

0.34

3.9

3.85

4.45

4.35

Full load conditions

A

0.9

0.8

1.8

1.8

21.2

22.8

23.9

25.4

kW

0.19

0.16

0.36

0.34

4.48

4.52

5.03

5.02

Starting amperes

A

2

2

2

2

131

131

133.9

133.8

Electrical characteristics

Electrical Data

Advertising