Sanyo KH2442 / CH2442 User Manual

Page 120

Advertising
background image

I - 116

SM830082

1

2

3

4

5

1. Specifications

Cooling:

Rating Conditions

: Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature

95

°

F DB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature 115

°

F DB

Heating:

Rating Conditions

: Indoor Air Temperature

70

°

F DB / 60

°

F WB

Outdoor Air Temperature

47

°

F DB / 43

°

F WB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / —

°

F WB

Outdoor Air Temperature

45

°

F DB / 35

°

F WB

Indoor model: KH3642 / Outdoor model: CH3642

Cooling

Heating

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.5 - 0.5

1.8 - 1.8

12.6 - 13.2

14.9 - 15.5

kW

0.10 - 0.09

0.36 - 0.34

2.83 - 2.69

3.29 - 3.12

Full load conditions

A

0.5 - 0.5

1.8 - 1.8

15.4 - 16.8

17.7 - 19.1

kW

0.10 - 0.09

0.36 - 0.34

3.45 - 3.38

3.91 - 3.81

Starting amperes

A

1 - 1

2 - 2

95 - 86

97.5 - 88.5

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.5 - 0.5

1.8 - 1.8

15.5 - 16.8

17.8 - 19.1

kW

0.10 - 0.09

0.36 - 0.34

3.40 - 3.38

3.86 - 3.81

Full load conditions

A

0.5 - 0.5

1.8 - 1.8

14.7 - 16.0

17 - 18.3

kW

0.10 - 0.09

0.36 - 0.34

3.32 - 3.29

3.78 - 3.72

Starting amperes

A

1 - 1

2 - 2

95 - 86

97.5 - 88.5

Advertising