1. Specifications

1-2 Major Component Specifications

(B) Outdoor Unit

MODEL No.

CH3642

Source

230 - 208 VAC / 1 phase / 60 Hz

Controller P.C.B. Ass'y

CR - CH2442 (Microprocessor)

Control circuit fuse

250 V, 3 A

Compressor

Rotary (Hermetic)

Model

C - R221H6R

Source

230 - 208 VAC / 1 phase / 60 Hz

Nominal output

W

2,200

Compressor oil

cc

1,500

Coil resistance (Ambient temperature 77

°

F)

C – R : 0.549 , C – S : 1.525

Safety device

Internal type

Overload relay models

Operating temperature

Open

°

F

320

±

9

Close

°

F

189

±

20

Operating ampere (at 77

°

F)

A

Run capacitor

VAC,

µ

F

400 VAC, 40

µ

F

Crank case heater

VAC,

W

230 VAC, 30 W

Refrigerant amount charged at shipment

lbs.

(kg)

R22 : 8.82 (4.0)

High pressure switch

ACB - 1UB11

Set pressure

OFF lb/in

2

(kg/cm

2

)

426.6

(30 )

ON

lb/in

2

(kg/cm

2

)

341.3

±

28.44 (24

±

2.0)

Fan

Propeller

Number...diameter

in.

(mm)

2 ... 18 - 3/32 (460)

Fan speeds

2 (AUTO)

Fan motor

Model

KFC6T - 91D6P

×

2

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole ..... rpm (230 V, High)

6 ... 879

Nominal output

W

110

×

2

Coil resistance

BRN – WHT : 67.14 , VLT – YEL : 11.42

(Ambient temperature 68

°

F)

WHT – VLT

: 64.85 , YEL – PNK : 10.60

Safety device

Internal type

Operating temperature

Open

°

F

248

±

9

Close

°

F

171

±

27

Run capacitor

VAC,

µ

F

440 VAC, 4

µ

F

×

2

Heat exchange

Coil

Aluminum plate fin / Copper tube

Rows ..... Fins per inch

2 ... 14.1

Face area

ft.

2

(m

2

)

11.63 (1.08)

DATA SUBJECT TO CHANGE WITHOUT NOTICE

+

28.44

+

7.11

+ 2.0
+ 0.5