1. Specifications
HP
High
pressure
switch
Compressor
Accumulator
EC
P
Heat exchanger
4-way valve
EC
P
Heat exchanger
Distributor
Electronic
ref.control
valve
Strainer
Liquid line
nipple
Liquid line
service
valve
O.D.
3/8"
(9.52mm)
O.D.
3/4"
(19.05mm)
Gas line
nipple
Gas line
service
valve
Distributor
Sub-heat exchanger
Cooling Cycle
Heating Cycle
Strainer
M
2181_THS_I
Muffler
1-5 Refrigerant Flow Diagram
Outdoor Unit: CH4242
Indoor Unit: 42 Type
1-6 Operating Range
Temperature
Indoor Air Intake
Outdoor Air Intake
Cooling
Maximum
95
°
F DB, 71
°
F WB
115
°
F DB
Minimum
67
°
F DB, 57
°
F WB
0
°
F DB
Heating
Maximum
80
°
F DB, 67
°
F WB
75
°
F DB, 65
°
F WB
Minimum
-DB / -WB
17
°
F DB / 15
°
F WB
Advertising