Sanyo KH2442 / CH2442 User Manual

Page 111

Advertising
background image

I - 107

SM830082

1

2

3

4

5

1. Specifications

Cooling:

Rating Conditions

: Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature

95

°

F DB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature 115

°

F DB

Heating:

Rating Conditions

: Indoor Air Temperature

70

°

F DB / 60

°

F WB

Outdoor Air Temperature

47

°

F DB / 43

°

F WB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / —

°

F WB

Outdoor Air Temperature

45

°

F DB / 35

°

F WB

Indoor model: XH2442 / Outdoor model: CH2442

Cooling

Heating

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.6 - 0.6

0.9 - 0.9

9.7 - 10.1

11.2 - 11.6

kW

0.12 - 0.11

0.18 - 0.17

2.15 - 2.07

2.45 - 2.35

Full load conditions

A

0.6 - 0.6

0.9 - 0.9

11.1 - 12.0

12.6 - 13.5

kW

0.12 - 0.11

0.18 - 0.17

2.50 - 2.47

2.80 - 2.75

Starting amperes

A

1 - 1

1 - 1

66 - 60

68 - 62

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.4 - 0.4

0.9 - 0.9

10.4 - 11.0

11.7 - 12.3

kW

0.09 - 0.08

0.18 - 0.17

2.23 - 2.20

2.50 - 2.45

Full load conditions

A

0.4 - 0.4

0.9 - 0.9

10.8 - 11.7

12.1 - 13.0

kW

0.09 - 0.08

0.18 - 0.17

2.43 - 2.40

2.70 - 2.65

Starting amperes

A

1 - 1

1 - 1

66 - 60

68 - 62

Electrical characteristics

Electrical Data

Advertising