2. Processes and functions

(B) AUTO Control Mode

When the Compressor has stopped while in AUTO mode, the 4-way valve switches on
(heating) or off (cooling) within 1 minute according to the following conditions:

Fig. 16

2-12

Automatic Restart after Power Interruption

This air conditionner has a power failure recovery function.

Compressor has stopped

under the operation of

“AUTO mode” condition.

4-way valve delays its

switching for 30 – 50 seconds

after compressor has been

turned ON.

0446_M_S

SOLENOID COIL
(4-WAY VALVE)

COMPRESSOR

COOL

AUTO
MODE
CONTROL HEAT

OFF

OFF

OFF

OFF

POWER SOURCE

OPERATION
BUTTON

OFF

MORE THAN 10 MINUTES

(THERMO. OFF)

MORE THAN 10 MINUTES
(THERMO. OFF)

3 MINUTES

THERMO. OFF

THERMO. ON

MORE THAN

30 – 50 SECONDS

MORE THAN
3 MINUTES

OFF

OFF

MORE THAN
30 – 50 SECONDS

ON

ON

ON

ON

ON

HEAT

COOL

ON

ON

ON

HEAT

0445_M_S

Fig. 17