1) measurement of insulation resistance, 2 checking the electrical components – Sanyo KH2442 / CH2442 User Manual

Page 186

Advertising
background image

4. Service procedures

1

2

3

4

Section

SM830082

IV - 30

Fig. IV-14

Copper
tube or
metallic part

Clip

Insulation
tester

Probe

Terminal plate

0639_X_S

Fig. IV-15

Copper
tube or
metallic part

Clip

Insulation
tester

Probe

0640_X_S

Fig. IV-16

From fan motor,
compressor and other
parts.

Clip

Probe

Insulation
tester

Metallic
part

0641_X_S

Fig. IV-17

NOTE

Earthed wire

Clip

Probe

Insulation
tester

0638_X_S

(1) Measurement of Insulation

Resistance

• The electrical insulation is acceptable when the

resistance exceeds 1 M

.

1

1

1

1

1

Power Supply Wires

Clamp the earthed wire of the Power Supply wires
with a lead clip of the insulation resistance tester and
measure the resistance by placing a probe on either
of the power wires. (Fig. IV-14)

Then measure the resistance between the earthed
wire and the other power wires. (Fig. IV-14)

2

2

2

2

2

Indoor Unit

Clamp an aluminum plate fin or copper tube with the
lead clip of the insulation resistance tester and
measure the resistance by placing a probe on the
terminal plate (Fig. IV-15)

3

3

3

3

3

Outdoor Unit

Measure the resistance by placing a probe on the
terminal plate in the same manner as explained
above

2

. (Fig. IV-15)

4

4

4

4

4

Measurement of Insulation Resistance for
Electrical parts

• Disconnect the connector of the desired electric part

from terminal plate, P.C.B. Ass’y, etc. (Fig. IV-16)

• Similarly, disconnect the lead wires from

compressor, capacitor, etc. (Fig. IV-17)

• Measure the resistance in the same manner as

illustrated on the right.

Refer to Electrical Wiring Diagram.

If the probe does not enter the hole because the
hole is too narrow, use a probe with a thinner pin.

4-2

Checking the Electrical Components

Advertising