Sanyo KH2442 / CH2442 User Manual

Page 25

Advertising
background image

I - 21

SM830082

1

2

3

4

5

1. Specifications

1-2 Major Component Specifications

(A) Indoor Unit

MODEL No.

KH3642

Source

230 - 208 V / 1 phase / 60 Hz

Remote controller (Option)

RCS - BH80UA, WL

Controller P. C. B Ass'y

CR - TH2442

Control circuit fuse

250 V, 3 A

Switch Ass'y

SW - KHS2432

Fan

Cross-flow

Number ... Dia. and length

in.

(mm)

1 ... O.D. 4-13/18 (120), L46 (1,170)

Fan motor

Model

SFG4Q - 41B6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole … r.p.m. (230 V, High)

rpm

4 ... 1,273

Nominal output

W

50

Coil resistance

GRY - WHT

: 122.3

,

ORG - YEL

:

23.03

(Ambient temperature 68

°

F)

WHT - VLT

:

15.98

,

YEL

- PNK

:

9.272

VLT

- ORG

:

11.93

,

Safety device

Operating temperature

Open

°

F

266

±

14.4

Close

°

F

174.2

±

26

Run capacitor

VAC,

µ

F

440 V , 4

µ

F

Electronic expansion valve

Coil

EKV - MOZS557E0

Coil resistance

ORG - GRY

:

46

,

YEL

- GRY

:

46

(Ambient temperature 68

°

F)

RED - GRY

:

46

,

BLK

- GRY

:

46

Valve body

HKV - 30D26

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows … Fins per inch

3 … 12.7

Face area

ft.

2

(m

2

)

3.23 (0.3)

Louver Motor

Model

M2EA24ZA01

Rating

208 to 230 V, 60 Hz

No. of pole … rpm

8 … 3

Output

W

2.5

Coil resistance (Ambient temperature 68

°

F)

k

16.45

±

8 %

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Advertising