1. Specifications
1-9 Performance Charts
●
Cooling Characteristics
(2) Operating Pressure
1
1
1
1
1
Indoor Unit: 24 Type
Outdoor Unit: CH2442
•
High Pressure
High pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
Outdoor fan speed
Low
High
1161_X_S
85 (30)
80 (27)
75 (24)
70 (21)
Discharge pressure (psig)
300
320
340
220
200
240
260
280
180
160
59
68
77
86
95
104
(15)
(20)
(25)
(30)
(35)
(40)
Outdoor ambient temp.
°
F (
°
C)
Indoor
temp.
°
F (
°
C)
•
Low Pressure
Low pressure characteristics versus outdoor ambient temperature and indoor temperature.
(Indoor relative humidity: 50%, Indoor fan speed: High)
230V / 208V
1162_X_S
Indoor
temp.
°
F (
°
C)
Suction pressure (psig)
70
60
80
90
100
50
40
59
68
77
86
95
104
(15)
(20)
(25)
(30)
(35)
(40)
Outdoor ambient temp.
°
F (
°
C)
85 (30)
80 (27)
75 (24)
70 (21)
Outdoor fan speed
Low