4–54

Configuration Menus

NOTE: Host margin and tab settings will not be ignored whether or not

HOST OVERRIDE is enabled.

DISABLE allows certain host commands (line length, forms length, LPI,

CPI, print quality, and text orientation) to override operator panel

settings. Note that the information appearing on the message display

may

not

match the data stream setting. No values will change upon

initial selection of the disable option.

ENABLE permits operator panel settings to override host data stream

commands.

Format Control

FORMAT CONTROL enables the printer to reflect the same spacing as CTPC

model printers after absolute and relative move commands are executed. The

following options are available:

DISABLE reflects distance, generated by the IGP/VGL feature, IGP/PGL

feature, and Hex Transparent control code sequence, in the new

position (after absolute and relative move commands are executed).

ENABLE does not reflect distance, generated by the IGP/VGL feature,

IGP/PGL feature, and Hex Transparent control code sequence, in the

new position (after absolute and relative move commands are

executed).

Buffer Print

When enabled, the BUFFER PRINT parameter prints the EBCDIC data and

control codes received from the host as hex values. The output can be used to

troubleshoot printer data reception problems. Refer to Chapter 6 for information

on how to obtain a hex code printout.

NOTE: Use of this parameter may alter print attributes set by the host

computer. A power cycle may be required after changing BUFFER

PRINT from enable to disable.

Advertising