4–87

BC Check Digit

This option is used to configure if the host calculates the bar code check digit (“by

host”), and sends it along with the bar code, or if the bar code is sent without the

check digit, and the printer calculates and adds it. Note that if configured to “by

host,” the check digit is not verified by the printer, but printed as it was received.

Barcode darkmode

ENABLE: The bar codes will be printed at a higher resolution.

DISABLE: The bar codes are printed at lower resolution but at a higher

speed.

PUM Default

This is the “unit of measure” as it is used within the ANSI emulation. Coordinates

received in ESC sequences can be sent in two UOM’s: Decipoints, which is a unit

of 1/720 inch, or in lines or columns using the current LPI and CPI values. The

UOM used is determined by this configuration setting.

Truncate PI Slew

DISABLE: PI slews will be completed independent of their length.

TRUNCATE AT TOF: The slew is terminated when the next

Top–of–Form is reached. (This function applies to the ANSI EVFU only.)