Configuration Menus

4–25

Optimized Ratio

This option selects different bar code ratios for certain bar codes including Code 39

and Interleaved 2 of 5. It is included for compatibility with the IGP–X00 printers.

•

Enable. Select the alternate bar code ratios.

•

Disable. Use standard bar code ratios.

Interleaved 2/5 Selection

This option is added to be compatible with a special IGP-X00 customization.

Usually, if Interleaved 2/5 bar codes have an odd number of digits, a leading zero

is inserted in front of the data. However, this special IGP-X00 customization adds

a space character at the end of the bar code instead.

•

Leading Zero. A leading zero is inserted in front of the data.

•

Trailing Space. A space is inserted at the end of the data instead of a

leading zero.

•

X2 DPD. When selected, I–2/5 bar code with a magnification X2 will use

the specially configured ratios 3:3:6:5 rather than 3:6:9:12 for

compatibility issues.

True Form Slew

This option is related to slewing within forms when using the P–Mode command.

Customers with new applications are advised to keep this option enabled.

•

Enable. Form length is accurate according to the form length parameter

in the CREATE command.

•

Disable. Form length is IGP–X00 compatible when using P–Mode.

Printer PI Line

This option enables the IGP to send down PI instructions to the printer to slew

the form.

•

Enable. Send down the PI instructions to the printer (LinePrinter Plus)

during form slew. This is IGP–X00 compatible.

•

Disable. Do not send PI instructions to the printer. LFs are sent instead.